infrastruktur:it-services:netvaerk:switch_setup [2013/04/01 00:19] Georg Sluytermaninfrastruktur:it-services:netvaerk:switch_setup [2013/04/08 15:47] – external edit 127.0.0.1
Line 1: Line 1:
 +====== Switch setup i Hal9k ======
 +//Denne side er begrænset til læsning for almindelige brugere//
  
 +I krydsfeltet er der 2 Dell-switche. Noter fra opsætning:
 +
 +<code>
 +en
 +conf
 +hostname sw1.hal9k.dk
 +vlan database
 +vlan 901
 +vlan 902
 +vlan 903
 +vlan 904
 +vlan 905
 +exit
 +interface vlan 901
 +name outside
 +exit
 +interface vlan 902
 +name "Wireless network"
 +exit
 +interface vlan 903
 +name "Cabled network"
 +exit
 +interface vlan 904
 +name "Server network"
 +exit
 +interface vlan 905
 +name "bmx-klubben"
 +exit
 +
 +enable password CHANGEME
 +interface vlan 904
 +ip address 10.42.4.2 255.255.255.0
 +ipv6 enable
 +ipv6 address 2001:16d8:dd56:4::2/64
 +exit
 +
 +ipv6 default-gateway fe80::20c:29ff:fe9e:fc49
 +
 +interface range ethernet all
 +port storm-control broadcast enable
 +port storm-control broadcast rate 50000
 +switchport mode access
 +switchport access vlan 903
 +spanning-tree portfast
 +exit
 +
 +interface ethernet g44
 +switchport mode access
 +switchport access vlan 904
 +exit
 +interface ethernet g45
 +switchport mode access
 +switchport access vlan 902
 +exit
 +interface ethernet g46
 +switchport mode access
 +switchport access vlan 901
 +exit
 +interface ethernet g47
 +switchport mode trunk
 +switchport trunk allowed vlan add 901
 +switchport trunk allowed vlan add 902
 +switchport trunk allowed vlan add 903
 +switchport trunk allowed vlan add 904
 +switchport trunk allowed vlan add 905
 +exit
 +
 +interface ethernet g48
 +switchport mode trunk
 +switchport trunk allowed vlan add 901
 +switchport trunk allowed vlan add 902
 +switchport trunk allowed vlan add 903
 +switchport trunk allowed vlan add 904
 +switchport trunk allowed vlan add 905
 +exit
 +
 +snmp-server location "Sofiendalsvej 80, 9220 Aalborg Oest, Denmark"
 +snmp-server community public
 +snmp-server contact "[email protected]"
 +snmp-server enable
 +
 +copy running-config startup-config
 +y
 +
 +
 +
 +
 +dir
 +copy tftp://10.42.4.123/image.ros image
 +copy tftp://10.42.4.123/image.rfb boot
 +show bootvar
 +boot system image-2
 +show bootvar
 +y
 +
 +############################
 +In webinterface:
 +System -> Management Security -> Enable Password     (change the pw)
 +System -> Management Security -> Local user Database    (change the pw)
 +
 +</code>